Running the Installation Program - ironstream_for_micro_focus_omi - 7.0

Ironstream for Micro Focus® OMi for IBM i Installation

Portfolio
Integrate
ft:locale
en-US
Product name
Ironstream for Micro Focus OMi for IBM i
ft:title
Ironstream for Micro Focus® OMi for IBM i Installation
Copyright
2021
First publish date
2007
ft:lastEdition
2024-09-06
ft:lastPublication
2024-09-06T06:27:49.159000

From an IBM i command line, enter the following command to create the Ironstream runtime library, EVIEW:

EVREL70/EVINSTALL

Press F4 to see the installation options, or use the defaults described below:

Parameter

Keyword

Default

Description

MMS Port

MMSPORT

9000

The TCP/IP port number which will be opened and listened on for connections from the MMS process on the Proxy Server. Enter any unused port number between 1024 and 49151. This number will be ignored if the installation is upgrading a previous version.

CS Port

CSPORT

9001

The TCP/IP port number which will be opened and listened on for connections from the CS process on the Proxy Server. Enter any unused port number between 1024 and 49151. This number will be ignored if the installation is upgrading a previous Ironstream version.

HCI Port

HCIPORT

9002

The TCP/IP port number which will be used for inter-process communications by jobs in the EVIEW subsystem. Enter any unused port number between 1024 and 49151. This number will be ignored if the installation is upgrading a previous Ironstream version.

Backup Library

BACKUPLIB

QGPL

The name of the library where a backup of the current EVIEW library will be saved with a savefile named EVIEW7SAVE. This parameter will only be used if the installation is upgrading a previous Ironstream version.

Use “*NONE” to skip the creation of a backup

savefile.