In addition to setting the trace level for the project, you can set the trace level for individual processes. This determines the level of information written to the cleanser or matcher log file (DIRCleanser.log or DIRMatcher.log) for each individual process.

Note: Separate log files are also created for each process, independent of the log information written to DIRCleanser.log and DIRMatcher.log. The location of these files is identified in the cleanser and matcher settings files (DIRCleanser.xml and DIRMatcher.xml). You cannot modify the level of information written to these process log files.

To set a trace option for a process

  1. In the tree view in the left pane of the Project Deployment Form, right-click on a process and select Edit Options... The Edit window opens.
  2. Select one of the following trace options to set the level of trace information written to the DIRCleanser.log or DIRMatcher.log for this process. Note that your selected trace options do not affect the trace information written to the process log file, which is identified in the Log File field of this window.
    Note: Leave this Trace option set to None, which is the default, unless the server that will process requests from this project will use either the Minimum or Default processing level.
    Option Description
    None No trace information for this process will be written to the cleanser or matcher log file.
    Verbose open Lists the contents of the process's DDL (field name, offset or location in the buffer, field size).
    I/O buffers dump Dumps the input buffer in hex and ASCII before the Process call, and dumps the output buffer in hex and ASCII after the Process call.
    Process timers Turns on timers for the indicated process. Each process can have high resolution timers for the entry and exit of underlying Open, Process, Close, BuildInput buffer, and BuildOutput buffer methods.
    All Turns on all traces for this process.
  3. Click OK to close the window.
    Note: You cannot modify the settings file and log file names and locations in this window.