Switch on the Business Functions - trillium_quality - 17.1

Trillium Quality for SAP Field Extension Framework (ERP) Installation and Configuration Guide

Product type
Software
Portfolio
Verify
Product family
Trillium
Product
Trillium > Trillium Quality
Version
17.1
Language
English
Product name
Trillium Quality
Title
Trillium Quality for SAP Field Extension Framework (ERP) Installation and Configuration Guide
Topic type
How Do I
Overview
Configuration
Reference
Administration
Installation
First publish date
2008
To activate the SAP Field Extension Framework, you need to switch on the appropriate Business Functions.
Note: Perform the following procedure during a quiet time on your system. The activation can take some time and will cause many programs to require recompiling. We recommend locking all users during the activation process.

To switch on business functions

  1. Log on to your customizing client.
  2. Start transaction SFW5.
  3. Confirm the security information pop-up by clicking Continue.


  4. Expand the ENTERPRISE_EXTENSIONS node and you will see the two reversible Business Functions /TSSERP/EXTENSIONS and /TSSERP/ERPCUSTOMER. For CRM systems, you will only see /TSSERP/EXTENSIONS.


  5. Select the Planned Status checkbox for both /TSSERP/EXTENSIONS and /TSSERP/ERPCUSTOMER and click Check Changes. You should receive the message "No errors were found".


  6. Click Activate Changes.


    You will see the following pop-up which tells you that background job SFW_ACTIVATE_SF0X was started to activate the Business Functions.

  7. Similar to transactions SAINT and SPAM, you may encounter errors similar to the following after confirming the pop-up in SFW5. This is normal.


  8. You can restart transaction SFW5 to see the results of the activations. While the Business Functions appear to be active immediately in SFW5, they are not fully activated until job SFW_ACTIVATE_SF0X completes.


  9. Start transaction SM37 and monitor job SFW_ACTIVATE_SF0X until it completes. Depending on the capacity of you system, this job can run for 30 minutes or longer.


  10. After job SFW_ACTIVATE_SF0X completes, the Business Functions are fully activated. If necessary, you can review the DDIC and Switch Framework logs in transaction SFW5.