When the Reference Matcher process completes, it produces an output entity with reference match keys (reference_level1_key, reference_level2_key) and matched pattern numbers (reference_matched_lev1_pattern, etc) appended onto each record.

To specify pattern number output 

  1. Open the Reference Matcher process for editing.
  2. Select Process > Advanced > Reference Matching > Advanced.
  3. Click Pattern Number Output. The Pattern Number Output window displays.
  4. Select the Attribute in which to store level 1 pass pattern number. The default is reference_matched_lev1_pattern.
  5. Select the Attribute in which to store level 2 pass pattern number. The default is reference_matched_lev2_pattern.
  6. (Optional) Select the Attribute in which to store level 1 suspect pattern number. The default is reference_suspect_lev1_pattern.
  7. (Optional) Select the Attribute in which to store level 2 suspect pattern number. The default is reference_suspect_lev2_pattern.
  8. Click Attributes to Copy for more options.
  9. When you are satisfied with the settings, click Back
  10. Click Back again and click Finish.