Specifying Window Sizing - trillium_discovery - trillium_quality - 17.2

Trillium Control Center

Product type
Software
Portfolio
Verify
Product family
Trillium
Product
Trillium > Trillium Discovery
Trillium > Trillium Quality
Version
17.2
Language
English
Product name
Trillium Quality and Discovery
Title
Trillium Control Center
First publish date
2008
Last updated
2024-07-01
Published on
2024-07-01T08:56:48.630530

You can control how many rows are added to the match window. If there are more rows of one window key than the value specified, additional windows are created for the remaining rows. 

If you know which window keys are particularly large, an external cross-reference file can be used to break up a large number of window keys of the same value. See Using a Cross-reference File for details.

Note: When the max window size setting results in a match window being split, a warning message will be generated indicating the match results may not be complete.

To specify window sizing

  1. From the Navigation or Project View, right-click the Relationship Linker or Reference Matcher process and select Edit Process. The editing window displays.
  2. Select the Process tab.
  3. Click Advanced and select the Window Sizing tab.
  4. Select Split large windows into separate blocks.
  5. In Max window size for transaction file, specify a numeric value. For example, if you have 1000 rows of one window key and set the value at 500, additional match windows are created for the remaining 500 rows.'
  6. (Optional) The Lookup Key section is used for a cross-reference file. See Using a Cross-reference File for details.
  7. Click Back and click Finish.