The SOTRNGN option specifies the action to be taken in BetterGener applications if the LRECL defined in the JCL for SYSUT2 is smaller than the SYSUT1 LRECL or the internally processed record length when the SYSUT1 LRECL is modified by features.   

RC0

The delivered default specifies that BetterGener should issue a WER462I, truncate the output records, and issue a return code of zero.   

RC4

Specifies that BetterGener should issue a WER462I and truncate the output records. A return code of 4 will be issued if not overridden by a higher return code set for another reason.   

IEB

Specifies that BetterGener should transfer control to IEBGENER when the SYS­UT2 LRECL is smaller than the SYSUT1 LRECL.