The following list the issues fixed in this version of Acquire for z/OS:
BugID |
Support Call ID(s) |
Notes |
---|---|---|
CM-8116 | Use the correct fields for software MSU calculation (SMF70CPA_scaling_factor and SMF70CPA_actual) in place of SMF70CPA | |
CM-8885 | Prevent double adjustment of time in 1302 job records when the TIMEADJUST= parameter is in use | |
CM-8906 | PRE-00666216 | Handle illogical DCOLLECT space data and avoid abending S0CB |
CM-8907 | PRE-00473776 | Avoid S0C4 processing job data in ACQATHJB + 83A |