Messages resulting in a U0911 or U0666 abends - syncsort_capacity_management - 12 - 12.40

Syncsort Capacity Management Installation Guide

Product type
Software
Portfolio
Integrate
Product family
Syncsort
Product
Syncsort Capacity Management
Version
12.40
Language
English
Product name
Syncsort Capacity Management
Title
Syncsort Capacity Management Installation Guide
Topic type
How Do I
Copyright
2023
First publish date
1985

Some error conditions are so serious that Acquire cannot continue and will force an abend U0911 or U0666. This is a list of the messages that can be printed just prior to abending. Those without a message number will appear at the top of the job log as opposed to in the //IPLIST file.

For all these issues, send the full job log including a SYSABEND dump to Precisely Support.

ACQUIRE:ACQAPUT - INVALID MONTH NAME POINTED TO BY R2

Meaning: A month value not in the range of 01 - to 12 has been detected when converting an SMF date to the standard Acquire printable form of ddMMMyy.

ACQUIRE:ACQAPUT - DSNAME IN ERROR, POINTED TO BY R2

Meaning: A dataset name for the //ATHDATA file seems to contain more than 44 characters. This is not expected.

ACQUIRE:ACQAPUT BAD USS FILE SIZE POINTED TO BY R2

Meaning: The size of a compressed USS file is too large for Acquire to handle.

ACQUIRE:ACQAPUT OUTPUT RECORD ERROR, CANNOT CONTINUE

Meaning: An output record has been created that is longer than the LRECL of the //ATHDATA file.

ACQUIRE:ACQAPUT ERROR ACCESSING USS, CANNOT CONTINUE

Meaning: While access the UNIX subsyste,m an error has occurred, but USSONLY=Y is in effect so there nowhere else Acquire can write to.

ACQUIRE:ACQATHCF MORE THAN 63 COUPLING FACILI­TIES

Meaning: More than 63 Coupling Facility devices have been detected. Acquire will need to be amended to cater for a larger number.

ACQUIRE:ACQATHCF COULD NOT MATCH CF TO STRUCTURE

Meaning: A Coupling Facility structure has been found for which there was no Coupling Facility detail.

ACQUIRE:ACQATHCF STRUCTURE TABLE IS FULL

Meaning: The internal Coupling Facility structure table has filled up. Acquire will need to be amended to cater for a larger number.

ACQUIRE:ACQATHHC - INVALID MONTH NAME POINTED TO BY R2

Meaning: A month value not in the range of 01 - to 12 has been detected when converting an SMF date to the standard Acquire printable form of ddMMMyy.

ACQUIRE:ACQATHHI UNKNOWN COUNTER 2 VERSION IN R3

Meaning: In examining HIS data the Counter 2 value is not recognized. This is most likely because you are running on a brand new IBM processor type as yet not catered for by Acquire.

ACQUIRE:ACQEW06 UNHANDLED DBCS FOUND => R2

Meaning: In examining some ASCII double-byte data, a character with unexpected characteristics was found and cannot be handled in module ACQCEW06 (WebSphere).

ACQUIRE:ACQCE113 UNKNOWN COUNTER LENGTH IN R3

Meaning: In examining HIS data a counter was found that was neither 4 or 8 bytes long. This is unexpected.

ACQUIRE:ACQCE70 UNKNOWN PROCESSOR TYPE POINTED BY R2

Meaning: In examining LPAR data, the processor type is not recognized. This could be because IBM have announced a new processor type as yet not catered for by Acquire but may be a result of memory corruption or bad SMF data.

ACQUIRE:ACQCE70P UNKNOWN PROCESSOR TYPE POINTED BY R2

Meaning: In extracting information from LPAR data, the processor type is not recognized. This could be because IBM have announced a new processor type as yet not catered for by Acquire but is more likely to be a result of memory corruption or bad SMF data.

ACQUIRE:ACQCE73 UNKNOWN CMG TYPE POINTED TO BY R2

Meaning: In examining channel path data a type of channel management block has been found that is currently unknown to Acquire. This could be because IBM have announced a new CMG type as yet not catered for by Acquire, but is more likely to be a result of memory corruption or bad SMF data.

ACQUIRE:ACQCICS OFFCOUNT(R2) DOES NOT MATCH NAMTAB#(R3)

Meaning: The number of items in two tables does not match, and they must.

ACQUIRE:ACQCRUN DATABOX OPEN ERROR, CODE IS IN R2

Meaning: An ES/1 databox was opened but returned a non-zero return code.

ACQUIRE:ACQSRUN DATABOX GET ERROR, CODE IS IN R2

Meaning: An ES/1 databox was opened but when read returned a non-zero return code.

ACQUIRE:ACQCRUN DATABOX CLOSE ERROR, CODE IS IN R2

Meaning: An ES/1 databox was processed but when closed but returned a non-zero return code.

ACQUIRE:ACQDB2 DB2 TRANSACTION TABLE FULL

Meaning: An internal table holding up to 16384 DB2 transaction names has become full.

ACQUIRE:ACQES1DB DATABOX READER LOAD ERROR SEE R2/R3

Meaning: The ES/1 databox reader program could not be loaded into memory.

ACQUIRE:ACQLISTC DATASET TABLE IS FULL

Meaning: The ES/1 databox reader program could not be loaded into memory.

ACQUIRE:ACQPP INTERNAL TABLE IS FULL (=> R3)

Meaning: The table of included or excluded CICS or DB2 subsystems has been filled up.

ACQUIRE:ACQPPTG INTERNAL TABLE IS FULL (=> R2)

Meaning: The table of system/targets has been filled up.

ACQUIRE:ACQSORT SORT HAD A NON-ZERO RETURN CODE

Meaning: The SORT utility failed - check its own messages to examine why.

ACQUIRE:ACQSRUN # SCAN COUNTERS NOT EQUAL # LABELS

Meaning: An internal error check has found a mismatch in two tables.

ACQUIRE:ACQSRUN # WORK COUNTERS NOT EQUAL # LABELS

Meaning: An internal error check has found a mismatch in two tables.

ACQUIRE:TXT2ADD - INTERNAL TABLE FULL => R2

Meaning: A textstring-to-address table has become full.