Advanced Transformer rules can be configured and passed at runtime if they are exposed as dataflow options. This enables you to override the existing configuration with JSON-formatted strings. You can also set stage options when calling the job through a process flow or through the job executor command-line tool.

You can find schemas for AdvancedTransformerRules in the following folder:

<Spectrum Location>\server\modules\jsonSchemas\advancedTransformer

To define Advanced Transformer rules at runtime:

  1. In Enterprise Designer, open a dataflow that uses the Advanced Transformer stage.
  2. Save and expose that dataflow.
  3. Go to Edit > Dataflow Options.
  4. In the Map dataflow options to stages table, expand Advanced Transformer. Check the box for AdvancedTransformerRules.
  5. Optional: Change the name of the options in the Option label field.
  6. Click OK twice.