The DCE RMF Filter panel in the Ironstream Desktop (IDT) GUI provides the option to collect Enclave metrics from the RMF Distributed Data Server (DDS). Enclave Attributes can be enabled/disabled per LPAR within a Sysplex.
When activated, the Enclave Attributes collect the Enclave metrics from the RMF DDS, which are logged by DCE and forwarded to a data repository.
The Enclave data format defaults to JSON but it can also be formatted as XML by modifying the DataFormat configuration parameter in the RMFSettings group.
For more information, see “Setting Up the RMF Data Forwarder” in the Ironstream Configuration and User’s Guide.