Message Variables
count
Number of SMF records lost
Message Description
This message displays the number of SMF records that were received but not recorded due to a lack of room in the Ironstream dataspace.
System Action
Processing continues.
User Action
If count
is greater than 0, consider either (1) increasing the frequency that the SMF subtask reads and clears the dataspace by lowering the INTERVAL value of the SMF parameter card in SYSIN
, or (2) increasing the size of the dataspace by modifying the SMFDATASPACE parameter card in SYSIN
.