EVO181 Exitname Exit Unable to Write SMF Record - ironstream_for_servicenow_discovery_1 - 7.5

Ironstream for ServiceNow® Discovery for IBM Z® Administration

Product type
Software
Portfolio
Integrate
Product family
Ironstream
Product
Ironstream > Ironstream for ServiceNow® Discovery
Version
7.5
Language
English
Product name
Ironstream for ServiceNow® Discovery for IBM Z®
Title
Ironstream for ServiceNow® Discovery for IBM Z® Administration
First publish date
2007
Last updated
2024-11-18
Published on
2024-11-18T05:02:12.928000
Message Variables
exitname Load module name of the exit program, one of: EVIEFU83, EVIEFU84, EVIEFU85

Message Description

An SMF exit program attempted to copy an SMF record to the Ironstream dataspace, but was unable due to size restrictions.

System Action

The SMF record is dropped and will not be processed by Ironstream.

User Action

The most common cause of this error is that the dataspace is too small to hold the SMF record(s) that the exit program is trying to copy. Either increase the size of the dataspace (the default size is 10 million bytes) using the "SMFDATASPACE" parameter card in the SYSIN deck, or increase the frequency that the dataspace is polled by reducing the INTERVAL option on the “SMF” parameter card in the SYSIN deck.