Message Variables
type Subtask type ("MVS" or "CMD")
name Name of console to be defined
rc Return code from initialization routine, in hexadecimal
reas Reason code from initialization routine, in hexadecimal

Message Description

The initialization of the console failed.

System Action

The VP390 subtask terminates with a condition code 8.

User Action

Verify that all the parameters on the type SYSIN card conform to the syntax rules. If rc=4, then a console name is already running. If you are running multiple Ironstream agents on mainframes or LPARs in a sysplex, then one mainframe image may be able to see another's consoles. Use a unique name for each agent's MVS and CMD card in its SYSIN deck. If rc =10, verify that name conforms to the rules for console names. If rc =C, the VP390 task does not have the necessary READ access to the OPERCMDS resource name MVS.MCSOPER.name. Enter the RACF command to allow this READ access for the user ID under which the VP390 job is running.