EVO091 PPI Initialization Failed, step = stepnum RC = rcnumber - ironstream_for_servicenow_discovery_1 - 7.5

Ironstream for ServiceNow® Discovery for IBM Z® Administration

Product type
Software
Portfolio
Integrate
Product family
Ironstream
Product
Ironstream > Ironstream for ServiceNow® Discovery
Version
7.5
Language
English
Product name
Ironstream for ServiceNow® Discovery for IBM Z®
Title
Ironstream for ServiceNow® Discovery for IBM Z® Administration
First publish date
2007
Last updated
2024-11-18
Published on
2024-11-18T05:02:12.928000
Message Variables
stepnum Initialization step that failed:
  1. SSI not running
  2. Attempt to get ASCB value failed
  3. Attempt to register receiver failed
rcnumber Return code from call to CNMNETV

Message Description

An attempt by the PPI subtask to access the CNMNETV module failed.

System Action

The PPI subtask terminates with a condition code 6.

User Action

If stepnum = 1, check the status of the SSI address space. If stepnum = 2, use the NetView DISPLAY PPI modiFy command to verify that the NetView program-to-program interface is active. If stepnum = 3, verify that no other application is attached to the NetView/390 or NETMASTER PPI.