EVO133 Unable to collect queue queue data: error accessing source, rc=code - ironstream_for_micro_focus_universal_discovery - 7.4

Ironstream for Micro Focus® Universal Discovery for IBM Z® Administration

Product type
Software
Portfolio
Integrate
Product family
Ironstream
Product
Ironstream > Ironstream for Micro Focus® Universal Discovery
Version
7.4
Language
English
Product name
Ironstream for Micro Focus Universal Discovery for IBM Z
Title
Ironstream for Micro Focus® Universal Discovery for IBM Z® Administration
Copyright
2022
First publish date
2007
Last updated
2023-08-23
Published on
2023-08-23T16:22:42.216801

Message Variables

queue Queue name to gather information from: "INPUT", "OUTPUT", or "HELD"

source Resource that could not be accessed: "ISFIN", "ISFOUT", or "SDSF"

code Return code

Message Description

The ev390hostcmd utility on the OVOW server sent a type 46 command requesting information from one of the JES2 queues that could not be supplied.

System Action

Processing continues.

User Action

If source is "ISFIN" or "ISFOUT", verify that the ISFIN and ISFOUT DD cards are correctly defined in the VP390 startup JCL. The code can have different meanings depending on the type 46 option that was requested. Identify what command request is being issued, and contact Precisely support.