Phase 2: Updating CNMPROC - ironstream_for_micro_focus_omi - 7.2

Ironstream for Micro Focus® OMi for IBM Z® Installation

Product type
Software
Portfolio
Integrate
Product family
Ironstream
Product
Ironstream > Ironstream for Micro Focus® OMi
Version
7.2
Language
English
Product name
Ironstream for Micro Focus OMi for IBM Z
Title
Ironstream for Micro Focus® OMi for IBM Z® Installation
Copyright
2021
First publish date
2007
Last updated
2025-01-16
Published on
2025-01-16T06:22:08.986000

To enable Ironstream to receive alert information from SOLVE:NETMASTER, add the Network Control Language (NCL) code in hlq.CLIST(NETTKCNM) to the production CNMPROC at a point where all CNM flow can be seen. Add this code immediately after the mainline &CNMREAD. In the distributed CNMPROC ($NWCNMPR), the label ".READOK" is the point determining the &CNMREAD to be successful. Make sure to insert the NCL code immediately after .READOK label.