Update the CNMSTYLE member of DSIPARM as follows:

  1. In the section defining autotasks, add the following line:

AUTOTASK.EVOAUTO1.Console = *NONE*
  1. In the section defining optional tasks, add the following lines:

TASK.NTIPPI.MOD=NTIPPI 
TASK.NTIPPI.PRI=8 
TASK.NTIPPI.INIT=Y
  1. If the DSIEX06 or DSIEX11 exits were assembled in Phase 2 above and are expected to be used, then change the LOADEXIT parameter for the exit(s) from "No" to "Yes".