Description - ironstream_for_micro_focus_omi - 7.2

Ironstream for Micro Focus® OMi for IBM Z® Installation

Product type
Software
Portfolio
Integrate
Product family
Ironstream
Product
Ironstream > Ironstream for Micro Focus® OMi
Version
7.2
Language
English
Product name
Ironstream for Micro Focus OMi for IBM Z
Title
Ironstream for Micro Focus® OMi for IBM Z® Installation
Copyright
2021
First publish date
2007
Last updated
2025-01-16
Published on
2025-01-16T06:22:08.986000

This card will initialize a NOMATCH subtask, which is responsible for writing any mainframe messages that were not passed on to the OMi server due to a defined filtering restriction. The logging datasets will be written in the following format:

Column

Data

1

Reason for the filtering (in this order of precedence):

M MVS message had the MPF suppression flag set, and the DROP_MPF_SUPPRESSED parameter card indicated that these messages are to be suppressed and logged.

H MVS message had the Hardcopy Only flag set, and the DROP_HARDCOPY_ONLY parameter card indicated that these messages are to be suppressed and logged.

E MVS message had the WTO User Exit suppression flag set, and the DROP_WTO_USER_EXIT_SUPPRESSED

parameter card indicated that these messages are to be suppressed and logged.

A MVS message had the Automation Requested flag set, and the DROP_AUTOMATION_FLAGGED parameter card indicated that these messages are to be suppressed and logged.

S MVS message had the SSI flag set, and the DROP_SSI_SUPPRESSED parameter card indicated that these messages are to be suppressed and logged.

V Message ID was not in the Ironstream message filter table.

3-9

Date of message in Julian format: YYYYDDD

11-18

Time of message in HH.MM.SS

20-27

Job name which produced message, if any

29-36

Originating system name of message, if available

38-45

Job ID which produced message, if any

47

MVS high intensity character (*or @), if any

48

Message Text

Parameters

Parameters

Value

logn

The DD names of the logging datasets. Up to ten DD names may be specified. Each name given must match a DD card definition in the VP390 job’s started task JCL, and each logging dataset should be predefined with DCB=(DSORG=PS,RECFM=V,LRECL=1651).