Use the FILTERTABLE card to set the number of message ID entries allowed in the message filter table. If this card is not present, the message filter table will default to allow 2000 message IDs.

The FILTERTABLE card should only be used once, and it must be specified in the SYSIN deck

ahead of any FILTER cards.

Parameters

Parameter

Description

MSGSIZE=entries

Specify the maximum number of entries in the message filter table. entries must be an integer between 1 and 500000.