These are error messages that may be generated by the jobs running on the Ironstream Agent for IBM i:

Message ID

EVM0001

Text

Invalid Reply. Please contact your System Administrator

Description

A reply was sent for a message that is not on the queue, perhaps because the message had already been answered

Inserts

None

Severity

99

Type

Info

System Action

Processing continues

User Action

Contact your system administrator to reply to the message on the agent

Message ID

EVM0007

Text

queue limit reached, queue cleared

Description

Maximum number of records were written to the queue. This is most likely due to the Management Server not being connected to the agent

Inserts

queue Name of queue

Severity

99

Type

Info

System Action

Queue is cleared. Processing continues

User Action

If this appears repeatedly, contact Precisely support

Message ID

EVM0015

Text

***WARNING*** Processing has ended due to the possible loss of connectivity

Description

This message is generated when a data queue requires clearing. The message gives the option of (A) clearing the data queue, or (B) ending the EVSBS subsystem entirely

Inserts

None

Severity

99

Type

Inq

System Action

Clearing the queue or ending the subsystem

User Action

Respond "A" or "B" to the message

Message ID

EVM0017

Text

Message queue queue was not cleared

Description

The request to clear the message queue failed

Inserts

queue Name of queue

Severity

99

Type

Info

System Action

Processing continues

User Action

Run the CLRMSGQ command manually to find the error explaining why the clear attempt failed

Message ID

EVM0100

Text

EVCMSG: Error converting version message, return code-code

Description

An error occurred when executing character set conversion functions

Inserts

code Return code from EVTCTLPROC job

Severity

99

Type

Info

System Action

The EVTCTLPROC job terminates

User Action

Look for an error message in the EVIEW/EVTRACE output queue from the EVTCTLPROC job. Contact Precisely support

Message ID

EVM0101

Text

port: Invalid or missing value in parameter

Description

The port parameter does not exist in the EVPARMS file or the value is not a valid numeric value

Inserts

port Port value read from the EVPARMS file

Severity

99

Type

Info

System Action

The EVTCTLPROC job terminates

User Action

Correct the parameter and restart the agent

Message ID

EVM0160

Text

EVCQSCAN: Invalid scan interval specified - setting to 5 seconds

Description

The scan interval specified for the EV400_QSCAN_INTERVAL is not a valid numeric value

Inserts

None

Severity

20

Type

Info

System Action

Default value is used and processing continues

User Action

Correct the parameter and restart the subsystem

Message ID

EVM0161

Text

EVCQSCAN: Failed creating message queue configuration user space, exception code msg

Description

The creation of a user space for the EVMSGQMON job failed

Inserts

msg Error message ID of the creation attempt

Severity

99

Type

Info

System Action

The EVMSGQMON job terminates

User Action

Consult IBM documentation for explanation of the msg

Message ID

EVM0162

Text

EVCQSCAN: Unable to open EVMSGQCFG file

Description

The message queue configuration file EVMSGQCFG could not be opened

Inserts

None

Severity

99

Type

Info

System Action

The EVCQSCAN job terminates

User Action

Verify that the EVMSGQCFG file exists in the EVIEW library. Redistribute message queue configuration from the server if necessary

Message ID

EVM0163

Text

EVCQSCAN: Message queue table exceeds maximum size

Description

The internal table for holding message queues has exceed the maximum allocated size (100 queue names)

Inserts

None

Severity

99

Type

Info

System Action

Processing continues. No further queue names are added

User Action

Contact Precisely support

Message ID

EVM0164

Text

EVCQSCAN: Failed creating message filter user space, exception code -msg

Description

The creation of a user space for the EVMSGQMON job's message filter table failed.

Inserts

msg Error message ID of the creation attempt

Severity

99

Type

Info

System Action

The EVCQSCAN job terminates

User Action

Consult IBM documentation for explanation of the msg

Message ID

EVM0165

Text

EVCQSCAN: Message filter table exceeds maximum size

Description

The message filter table exceeds the allocated maximum size (2000 message IDs)

Inserts

None

Severity

99

Type

Info

System Action

Processing continues. No further message IDs are added

User Action

Contact Precisely support

Message ID

EVM0166

Text

EVCQSCAN: Invalid line in EVMSGQSCF - value

Description

An invalid line was read from the EVMSGQCFG file

Inserts

value The keyword containing the erroneous value

Severity

99

Type

Info

System Action

The EVMSGQMON job terminates

User Action

Verify the value conforms to syntax rules. Re-distribute the configuration from the server if necessary

Message ID

EVM0167

Text

EVCQSCAN: Message queuenamenot found

Description

EVCQSCAN could not find the message queue on this system

Inserts

name The library/queue name

Severity

99

Type

Info

System Action

The EVMSGQMON job terminates

User Action

Either create the message queue, or correct and re-distribute the list of message queues from the server

Message ID

EVM0170

Text

EVC070: Error creating status poll user space - Exception ID: msg

Description

The creation of a user space for the EVSRSCPROC job's message filter table failed

Inserts

msg Error message ID of the creation attempt

Severity

99

Type

Info

System Action

The EVSRSCPROC job terminates

User Action

Consult IBM documentation for explanation of the msg

Message ID

EVM0400

Text

EView/400 Health Check Message

Description

This message is generated when the EVHEALTHCK program is called to generate a heartbeat message

Inserts

None

Severity

0

Type

Info

System Action

Processing continues

User Action

None

Message ID

EVM4444

Text

Cannot allocate file file

Description

Restoration of default configuration file failed

Inserts

file File name

Severity

99

Type

Info

System Action

Processing continues

User Action

Release the lock on file and try your operation again

Message ID

EVM5555

Text

There is a lock on the EVIEW library. Verify that the EVSBS subsystem is ended

Description

This message is generated if there is a failure in the conversion of older versions of the configuration files to the current version

Inserts

None

Severity

99

Type

Inq

System Action

The conversion process terminates

User Action

Enter "I" to continue or "C" to cancel

Message ID

EVM7060

Text

Invalid object olib/ oname/ omem removed from monitoring in journal jlib/ jname.

Description

Either the object oname with member omem does not exist on this system, or it does exist and is not being journaled to jname

Inserts

olib Object library

oname Object Name

omem Object member

jlib Journal library

jname Journal name

Severity

40

Type

Info

System Action

The object is removed from monitoring in this journal

User Action

Either remove the olib/ oname (omem) object from the monitor configuration, or start journaling the object to journal jname. Then, re-distribute the journal configuration(s) using the Ironstream IBM i Configuration Tool, or restart the subsystem to restore the monitoring of this object