Referenced data is available in the Spectrum data format (.spd) and can be downloaded from data.precisely.com. It must be extracted and configured before the data is available for use. By default, one extractor is used. However, data can be extracted using multiple threads if the --t parameter is defined.
Format of the extract command:
extract --s "/location/to/spd/files" --d "/data" --t 4
Command | Parameter | Description |
---|---|---|
extract |
--s
|
location of the source .spd file |
--d
|
destination folder for the extracted data | |
--t , --number-extractors |
extract data using multiple threads default: 1 if --t parameter is not provided default: number of cpu if --t is provided but no value defined |
Examples
- Use default extractor count.
#extract data to "/data" extract --s "/location/to/spd/files" --d "/data"
- Use all CPU to extract.
#extract data to "/data" extract --s "/location/to/spd/files" --d "/data" --t
- Use specific number of extractors.
#extract data to "/data" extract --s "/location/to/spd/files" --d "/data" --t 4