Abend Code Abending Module Description
LP00 LPWN500C Transfer control attempted to program LPWN512C. The transfer control has failed. The program name might be missing from the CICS program Table (PPT). Check the installation again.
LP01 LPWN500C GETMAIN failure - required storage not available.
LP02 LPWN500C Link attempted to program LPWN502C, LPWN503C, LPWN504C, LPWN510C or FINALOL. The link has failed. The program name might be missing from the CICS Program Table (PPT). Check the installation again.
LP03 LPWN500C The load has failed for LPWN501C (the Finalist messages table). Same probable reason and correction needed as described above for Abend Code LP02.
LP04 LPWN500C Pseudo-conversational return failed - possibly because LPWN511C was LINKed to or XCTL'd to by a program that was LINKed to.
LP10 LPWN502C The caller (LPWN500C) did not pass a COMMAREA on the CICS link command.
LP11 LPWN502C The caller (LPWN500C) passed an invalid screen type indicator. Valid values are 2, 3, 4, and 5.
LP20 LPWN503C The caller (LPWN500C) did not pass a COMMAREA on the CICS link command.
LP21 LPWN503C The caller (LPWN500C) passed an invalid screen type indicator. Valid values are 2, 3, 4, and 5.
LP30 LPWN504C The caller (LPWN500C) did not pass a COMMAREA on the CICS link command.
LP32 LPWN504C Unexpected, fatal error from a CICS command.
LP40 LPWN505C, LPWN508C The caller (LPWN500C) did not pass a COMMAREA on the CICS link command.
LP41 LPWN505C, LPWN508C Load failure for LPWN501C.
LP42 LPWN505C, LPWN508C Link to LPWN507C failed.
LP50 LPWN506C The caller (LPWN500C) did not pass a COMMAREA on the CICS link command.
LP60 LPWN511C COMMAREA passed in XCTL to LPWN511C was too short to contain required passdata.
LP61 LPWN511C Link to tailoring code translator failed.
LP62 LPWN511C XCTL to LPWN500C failed.
LP70 LPWN512C COMMAREA passed from Windows to LPWN512C was not the expected length.
LP71 LPWN512C XCTL back to user program failed. Field PASSPGM is invalid.
LP80 LPWN507C COMMAREA not passed to LPWN507C during link.
LP81 LPWN507C Load failure on LPWN501C.
LP90 LPWN509C Wrong length COMMAREA passed to input exit stub.
LPA0 LPWN510C Wrong length COMMAREA passed to output exit stub.