Upgrading to the latest version of Data360 Analyze - Data360_Analyze - 3.16

Data360 Analyze Server Installation

Product type
Software
Portfolio
Verify
Product family
Data360
Product
Data360 Analyze
Version
3.16
Language
English
Product name
Data360 Analyze
Title
Data360 Analyze Server Installation
Copyright
2024
First publish date
2016
Last updated
2024-12-18
Published on
2024-12-18T21:00:21.163000

If you do not have an existing installation of Data360 Analyze, see Downloading and installing Data360 Analyze.

Prerequisites

  • Consider turning off any anti-virus software that may interrupt the installation process.

  • If you have specified a custom version of ls.brain.tempDir in the <Data360 Analyze site directory>/cust.prop, remove this line from the <Data360 Analyze site directory>/cust.prop and instead set this as the value of the ls.host.brain.tempDir property in the <Data360 Analyze site directory>/cust.prop file.
  • Locate the value of the ls.lae.shareRootDir property in the <Data360 Analyze site directory>/cust.prop and set this as the value of the ls.host.lae.shareRootDir property in the <Data360 Analyze site directory>/cust.prop. Remove the line for the ls.lae.shareRootDir from the <Data360 Analyze site directory>/cust.prop. Note that failing to update the property in the cust.prop and remove the entry from the cust.prop will only cause a problem if you are intending on using execution sandboxing and you are either on Windows or have changed the location from the default.
  • Ensure that you have enough space available for the Postgres database upgrade. During upgrade, Postgres requires 1.5 times the disk space of the current Postgres database size.

Breaking changes

  • The Microsoft SQL Server JDBC driver shipped with the installation has been upgraded from 9.X to 12.X. Note that the default for the 12.X drivers is to have TLS enabled. To disable TLS set the DBOptions property on the JDBC related nodes to encrypt=false. If using a self-signed certificate for SQL Server, DBOptions will need to be set to trustServerCertificate=true
  • The MariaDB driver has been upgraded from 2.7.X to 3.3.X. There are a number of changes to the JDBC URL parameters. The 2.7.X version is still shipped with the product as it is still supported by the MariaDB project and it can be made the default version used by the Data360 Analyze installation. However, the 2.7.X version will be End Of Life in 2025, and at that point will no longer be supported by Data360 Analyze.

Latest LTS releases and upgrade paths

When planning an upgrade, it is important to verify the compatibility of the current version with the target version. An upgrade path is only available if the target version was released after the current version. This ensures that all necessary updates and patches are included in the upgrade process. The following table outlines the latest LTS releases and their corresponding upgrade paths:
Table 1. Upgrade paths for LTS releases
Current version Target version Upgrade path validity
3.14.0 (or earlier) 3.16.0 Valid
3.12.4 3.16.0 Valid
3.12.4 3.14.0 Invalid (3.12.4 released after 3.14.0)