To start collector services for a system, do the following
Do one of the following:
From MIMIX Intermediate Main Menu, select option
2
(Work with Systems) and press Enter.From the Work with Application Groups display, use option
12
(Node entries). On the resulting Work with Node Entries display, press F7 (Systems).
The Work with Systems display appears. Type a
9
(Start) next to the system definition you want and press Enter.The Start MIMIX Managers display appears. At the Collector services prompt, verify the value is
*YES
and press Enter.