A master monitor job runs in the MIMIXSBS subsystem on each system and controls all other monitors and the MIMIX scheduler job on the same system. The master monitor does not appear in the list shown on the Work with Monitors display.

The autostart job entry created in the subsystem during installation automatically starts the master monitor job on that system. During normal operations, the Start MIMIX (STRMMX) and End MIMIX (ENDMMX) commands address the master monitor jobs and the monitors each job controls on all systems in the MIMIX installation.

  • The STRMMX command will start the master monitors on each system in a MIMIX installation. In turn, the master monitor on each system will start the MIMIX scheduler job and all monitors that are not disabled and which are configured to automatically start with the master monitor.

  • The ENDMMX command will end all monitors that are in an active state. Then, the MIMIX scheduler job and the master monitor on each system are ended.

You may also need to start or end a master monitor independently of other MIMIX jobs.