These instructions will end target journal inspection processes on a selected system. If the system is the target system for replication, the inspection process for the system journal is ended and all inspection processes are ended for the user journals identified as the target journal in data groups replicating to the system.
To end target journal inspection processes for a system, do the following
-
Do one of the following:
-
From MIMIX Intermediate Main Menu, select option
2
(Work with Systems) and press Enter. -
From the Work with Application Groups display, use option
12
(Node entries). On the resulting Work with Node Entries display, press F7 (Systems).
-
The Work with Systems display appears. Type a
10
(End) next to the system definition you want and press Enter.The End MIMIX Managers display appears. At the Target journal inspection prompt, verify the value is
*YES
and press Enter.