Errors using target journal defined by RJ link - assure_mimix - 10.0

Assure MIMIX Operations Guide

Product type
Software
Portfolio
Integrate
Product family
Assure
Product
Assure MIMIX™ Software
Version
10.0
Language
English
Product name
Assure MIMIX
Title
Assure MIMIX Operations Guide
Copyright
2023
First publish date
1999
Last updated
2024-03-12
Published on
2024-03-12T11:06:36.794496

If you receive errors when using a target journal defined by an RJ link, you may need to change the journal definition and journaling environment. This situation is caused when the target journal definition is created as a result of adding an RJ link based on a source journal definition which specified QSYSOPR as the threshold message queue.

If you receive errors when using the target journal, do the following:

  1. On the Work with Journal Definitions display, locate the target journal definition that is identified by the errors.

  2. Type a 5 (Display) next to the target journal definition and press Enter.

  3. Page down to see the value of the Threshold message queue.

    • If the value is QSYSOPR, press F12 and continue with the next step.

    • For any other value, the cause of the problem needs further isolation beyond this procedure.

  4. Type a 2 (Change) next to the target journal definition and press Enter.

  5. Press F9 (All parameters), then page down to locate the Threshold message queue and Library prompts.

  6. Change the Threshold message queue prompt to *JRNDFN and the Library prompt to *JRNLIB, or to other acceptable values.

  7. To accept the change, press Enter.