Ending journaling for data areas and data queues - assure_mimix - 10.0

Assure MIMIX Operations Guide

Product type
Software
Portfolio
Integrate
Product family
Assure
Product
Assure MIMIX™ Software
Version
10.0
Language
English
Product name
Assure MIMIX
Title
Assure MIMIX Operations Guide
Copyright
2023
First publish date
1999
Last updated
2024-03-12
Published on
2024-03-12T11:06:36.794496

Use this procedure to end journaling for data areas and data queues identified by object tracking entries.

This procedure invokes the End Journaling Obj Entries (ENDJRNOBJE) command. The command can also be entered from a command line.

To end journaling for data areas and data queues, do the following:

  1. Access the journaled view of the Work with DG Obj. Trk. Entries display as described in Displaying journaling status for data areas and data queues.

  2. From the Work with DG Obj. Trk. Entries display, type a 10 (End journaling) next to the object tracking entries you want. Then do one of the following:

    • To verify journaling using the command defaults, press Enter.

    • To modify the command defaults, press F4 (Prompt) and continue with the next step.

  3. The End Journaling Obj Entries (ENDJRNOBJE) display appears. The Data group definition and IFS objects prompts identify the object associated with the tracking entry you selected. Although you can change the values shown for these prompts, it is not recommended unless the command was invoked from a command line.

  4. Specify the value you want for the End journaling on system prompt. Press F4 to see a list of valid values.

    If journaling is ended on the source system, a journal entry will be generated into the user journal. As a result, replication processes will end journaling for these objects on the target system if the data group definition specifies *YES for Journal on target (JRNTGT).

  5. To use batch processing, specify *YES for the Submit to batch prompt and press Enter. Additional prompts for Job description and Job name appear. Either accept the default values or specify other values.

  6. To end journaling on the objects specified, press Enter.