You can manually request that MIMIX retry processing for a data group activity entry that has a status of *FAILED. The retry can be requested from either the Work with Data Group Activity display or from the Work with DG Activity Entries display.
To retry failed (error) activity entries, do the following:
From the Work with Data Groups display, type a
13
(Objects in error) next to the data group you want that has values shown in the Obj Errors column and press Enter.The Work with Data Group Activity display appears with a list of the objects in error for the data group selected. Type an
8
(Retry) next to the entry you want and do one of the following:To submit the retry request for immediate processing, press Enter. Then skip to Step 4.
To schedule the retry request for a time at which it is more likely to be successful, press F4 (Prompt).
On the Retry DG Activity Entries (RTYDGACTE) display, specify a value for the Time of day to retry prompt. Then press Enter.
You can specify a specific time within 24 hours. The scheduled time is based on the time on the system from which the request is submitted regardless of the system on which the activity to retry occurs. When you submit a retry request for a scheduled time, MIMIX will make the entry active and will wait until the specified time before retrying the request. The scheduled time is the earliest the request will be processed. Be sure to consider any time zone differences between systems as you determine a scheduled time. For additional information and examples, press F1 (Help).
The Confirm Retry of DG Activity display appears. Press Enter.
If failed activity entries occur frequently, consider using the third delay retry cycle. When the Automatic object recovery policy is enabled, a third retry cycle is performed using the settings in effect from the Number of third delay/retries and Third retry interval (min.) policies. These policies can be set for the installation or for a specific data group.