To display the status of a switch definition do the following:

  1. Use the procedure in Accessing the Work with Switch Definitions display to access the Work with Switch Definitions display.

  2. From the Work with Switch Definitions display, type a 15 (Status) next to the switch definition you want and press Enter.

  3. The Display Switch Status display appears. This display is automatically updated as changes to the status occur.

Figure 7. Displaying switch status

The example in the above figure shows how the following information is displayed.

  • The left-most box contains information about the production system.

  • The right-most box contains information about the backup system.

  • The center-top box indicates where users are attached.

  • The center-bottom box indicates the status of the group monitor associated with the switch definition.

  • The color blue indicates that the system or monitor is active.

  • The color red indicates that the system or monitor is inactive.