You may need to end the master monitor when cleaning up the runtime environment, or when a CustomerCare representative directs you to end the master monitor.
Ending the master monitor also causes all other active monitors to end. The MIMIX scheduler job is also ended.The ended monitors will not function correctly without the master monitor.
From the native user interface, the master monitor does not appear in the list shown on the Work with Monitors display. Use the following command, specifying the name of the MIMIX installation library:
installation-library/ENDMSTMON