Predefined conditions for event classes and their associated parameters - assure_mimix - 10.0

Assure MIMIX Monitor Reference

Product type
Software
Portfolio
Integrate
Product family
Assure
Product
Assure MIMIX™ Software
Version
10.0
Language
English
Product name
Assure MIMIX
Title
Assure MIMIX Monitor Reference
Copyright
2023
First publish date
1999
Last updated
2024-08-07
Published on
2024-08-07T11:10:39.245672

The predefined conditions for each event class are:

*INTERVAL - The specified time interval has passed, and optional subclass checking has been performed.

*TIME - The specified date and time has occurred.

*MSGQ - A specified message ID has arrived in the monitored message queue.

*JRN - A specified journal transaction has arrived in the monitored journal.

*GROUP - The predefined condition for a group monitor is that all monitors in the group, with the exception of DISABLED and INACTIVE monitors, have changed to a FAILED or FAILED/ACT status. When the last active monitor in the group (other than the group monitor itself) changes to a status of INACTIVE, FAILED, or FAILED/ACT the group monitor assesses whether to run the condition and event programs specified for the group monitor.

The following table identifies which parameters on the CRTMONOBJ command are used to define the event for each event class. The *GROUP event class is not shown because it does not require parameters to define the event.

Table 1. Parameters on CRTMONOBJ command that define the predefined condition for the specified event class

Parameters

Event Classes

  *INTERVAL *TIME *MSGQ *JRN

Time interval (sec.)

X

Interval subclass

X

Configuration object

X

Configuration type

X

Host address or alias

X

System definition

X

Transfer definition

X

Frequency

X

Scheduled date

X

Scheduled day

X

Scheduled time

X

Relative day of month

X

Message queue

X

Message identifier

X

Journal

X

Journal codes

X

Journal entry types

X