Configuring system settings for replication
MIMIX supports replication of a subset of the system settings available on IBM i systems. Also, some exceptions exist within the types of settings that MIMIX does support. See Supported system settings for details.
To configure system settings for replication, do the following from a management system:
-
From the MIMIX Intermediate Main Menu, type a
1
(Work with data groups) and press Enter. -
From the Work with Data Groups display, type a
20
(Object entries) next to the data group you want and press Enter. -
The Work with DG Object Entries display appears. Type a
1
(Add) next to the blank line at the top of the list and press Enter. -
The Add Data Group Object Entry display appears. Do the following:
-
For the System 1 library prompt, specify
*SYSSET
. -
For the System 1 object prompt, specify
*NONE
. -
For the Object type prompt, you must specify a value that is supported for system settings. See the table in Supported system settings for a list of possible values.
-
-
Press Enter.
The data group must be stopped and restarted to make the configuration changes available to replication processes.