Use this procedure when a configuration checklist directs you to start a newly configured data group for the first time. You should have identified the starting point in the journals with Establish a synchronization point when you synchronized the systems.
-
From the Work with Data Groups display, type a
9
(Start DG) next to the data group that you want to start and press Enter. -
The Start Data Group (STRDG) display appears. Press Enter to access additional prompts. Do the following:
-
Specify the starting point for user journal journal replication. For the Database journal receiver and Database large sequence number prompts specify the information you recorded in Step 5 of Establish a synchronization point .
-
Specify the starting point for system journal journal replication. For the Object journal receiver and Object large sequence number prompts specify the information you recorded in Step 6 of Establish a synchronization point .
-
Specify *YES for the Clear pending prompt.
-
-
If the data group participates in an application group, do the following:
-
Press
F10
(Additional parameters). -
At the Override if in data rsc. group prompt, specify
*YES
.
-
-
Press Enter.
-
A confirmation display appears. Press Enter.
-
A second confirmation display appears. Press Enter to start the data group.